Bench top Turbidity Meter (with built-in printer) LTM-C10

  • Measuring range (NTU) : 0 to 100, 0 to 200
  • Minimum readout value (NTU) : 0.01
  • Calibration point : 2
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light

Bench top Turbidity Meter (with built-in printer) LTM-C11

  • Measuring range (NTU) : 0 to 100, 0 to 200, 0 to 500
  • Minimum readout value (NTU) : 0.01
  • Calibration point : 3
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light
Bench top Turbidity Meter (with built-in printer) LTM-C12
  • Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500
  • Minimum readout value (NTU) : 0.001
  • Calibration point : 4
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light
Bench top Turbidity Meter (with built-in printer) LTM-C13
  • Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
  • Minimum readout value (NTU) : 0.01
  • Calibration point : 5
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light

Bench top Turbidity Meter (with built-in printer) LTM-C14

  • Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
  • Minimum readout value (NTU) : 0.001
  • Calibration point : 5
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light

Bench top Turbidity Meter (with built-in printer) LTM-C15

  • Measuring range (NTU) : 0 to 10, 0 to 100
  • Minimum readout value (NTU) : 0.001
  • Calibration point : 2
  • Sample volume : 18 to 20 ml
  • Principle method : 90° scattered light
Bench top Turbidity Meter LTM-B10
  • Measuring range (NTU) : 0 to 100
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 1
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Bench top Turbidity Meter LTM-B11
  • Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 3
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light

Bench top Turbidity Meter LTM-B12

  • Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 4
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light

Bench top Turbidity Meter LTM-B13

  • Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 5
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Bench top Turbidity Meter LTM-B14
  • Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Benchtop conductivity meter LBCM-A11
  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity resolution : 0.01, 0.1, 1
  • Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
  • Conductivity calibration points : 1 - 3 points

Benchtop Conductivity Meter LBCM-A13

  • Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
  • Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
  • TDS measurement range : 0.000 mg/L to 1000g/L
  • Salinity measurement range : 0.00 to 8.00 %
  • Temperature measurement range : -5.0 to 135.0 °C

Benchtop Conductivity Meter LBCM-A14

  • Conductivity Mode :
    Conductivity measurement range 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity accuracy ±1% F.S.
    Conductivity resolution 0.001, 0.01, 0.1, 1
    Conductivity calibration points 1 to 3 points
    Conductivity calibration solutions 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • TDS Mode :
    TDS measurement Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.01 to 1.00 (default 0.5)
    TDS Calibration points 3 points
  • Temperature Mode :
    Temperature range 0 to 105°C, 32 to 221°F
    Temperature accuracy ±1°C
    Temperature resolution 0.1°C, 0.1°F
    Temperature calibration points 1 point
    Temperature Compensation Range and Mode Manual or Automatic, 0 to 100°C , 32 to 212°F
    Temperature coefficient 0.0 to 10.0 % per °C
  • Cell constant : K=0.1, 1, 10
  • Power requirements : DC 9 V, using AC adapter, AC 220 V, 50 Hz
Benchtop Dissolved oxygen meter LBDO-A10
  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L
  • Resolution : 0.1 mg / L
  • Calibration points : 1 - 2 points
  • Sensor type : Polarographic DO probe
Benchtop Dissolved oxygen meter LBDO-A11
  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L
  • Resolution : 0.01 mg / L
  • Calibration points : 1 - 2 points
  • Sensor type : Polarographic DO probe

Benchtop Ion meter for K, LBIM-A23

  • Ion measurement range : K range: 1×106 - 1M, 0.04 -39000 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for Ag, LBIM-A22

  • Ion measurement range : Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for Br, LBIM-A14
  • Ion measurement range : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for Ca, LBIM-A13
  • Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for Cd, LBIM-A28

  • Ion measurement range : Cd range: 1×106– 1M, 0.01-11200 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for Cl, LBIM-A10

  • Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for Cn, LBIM-A21
  • Ion measurement range : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for Cu, LBIM-A27
  • Ion measurement range : Cu range: 1×108 - 1M, 0.06-6400 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for F, LBIM-A11

  • Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for I, LBIM-A26

  • Ion measurement range : I range: 1×108- 1M, 0.06 -127000 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for Na, LBIM-A12
  • Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for NH3 , LBIM-A20
  • Ion measurement range : NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for NH4, LBIM-A15

  • Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L

Benchtop Ion meter for Pb, LBIM-A25

  • Ion measurement range : Pb range: 1×108 – 0.1M, 0.2-20700 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Ion meter for S, LBIM-A24
  • Ion measurement range : S range: 1×107 - 1M, 0.003-32100 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
  • Calibration solutions : 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • TDS Mode :
    TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
  • Temperature Range : 0 to 105°C, 32 to 221°F

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • TDS Mode :
    TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
  • Salinity Mode :
    Salinity Range 0 to 10 ppt (maximum 80 ppt)
    Salinity Accuracy ± 1 % F.S.
    Measurement modes Seawater or practical salinity

Benchtop Multi-parameter Water Quality Meter LMPWM-A32

  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • mV Mode :
    mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
  • Conductivity Mode :
    Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
  • Dissolved Oxygen Mode :
    Dissolved Oxygen Range 0.00 to 20.00 mg/ L
    Dissolved Oxygen Accuracy ± 0.2 mg/ L
    Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
    Dissolved Oxygen Calibration Points 1 or 2 Points
    % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
    Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 to 50 g/ L
  • Temperature Range : 0 to 105°C, 32 to 221°F
Benchtop Multi-parameter Water Quality Meter LMPWM-A40
  • pH Mode :
    pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
  • ORP Mode :
    mV Range ± 2000 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1 mV, selectable
    mV Calibration Points 1 Point, only for relative mode
  • Ion Mode :
    Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection)
    Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
    Ion measurement resolution 0.001/0.01/0.1/1
    Ion measurement calibration points 2 to 5 points
    Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L
    Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction
  • Water Hardness Mode :
    Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3)
    Water hardness measurement accuracy ±1% F.S
    Water hardness measurement resolution 0.001/0.01/0.1/1
    Water hardness calibration points 2 to 5 points
    Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L
  • Temperature Mode :
    Temperature measurement range 0 to 105°, 32 to 212°F
    Temperature measurement accuracy ± 0.5°C, ± 0.9°F
    Temperature measurement resolution 0.1°C, 0.1°F
    Temperature measurement calibration points 1 point
Benchtop pH meter LBPM-A11
  • pH measurement range : 0.00 to 14.00 pH
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH
  • Calibration points : 2 points
  • Calibration solutions : USA (pH 4.0/7.00/10.01)

Benchtop pH meter LBPM-A20

  • pH measurement range : -1.00 to 15.00 pH
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH
  • Calibration points : 1-3 points
  • Calibration solutions : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Benchtop pH meter LBPM-B10

  • pH measurement range : -2.000 to 20.000 pH
  • pH accuracy : ± 0.002 pH
  • Calibration points : 1-5 points
  • Calibration solutions : USA, NIST, DIN or user defined
  • ORP measurement range : -1999.9 to 1999.9 mV
Benchtop pH Meter LBPM-B11
  • Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic
  • Hold function : Manual or automatic endpoint detection
  • Stability criteria : Standard or High-accuracy
  • Interval readings : 10, 30, 60 seconds, 10, 30 minutes or Off
  • Calibration due alarm : 1 to 31 days
Benchtop Water hardness meter LBWM-A10
  • Water hardness range : 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.
  • Calibration points : 2 to 5 points
  • Calibration solution : 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
  • Temperature range : 0 - 105 °C

BOD Meter LBOD-A10

  • Determination range :
    0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
  • Measurement error : Less or less than 10 %
  • Sample container/ bottle quantity : 1 to 6
  • Sample container/ bottle Capacity : 1000 ml
  • Repeatability : ≤ 10 %

Multi parameter water quality analyzer LMWA-A10

  • COD :
    COD determination range 2 to 10000 mg/ L
    COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit 0.1 mg/ L
    COD measurement time 20 minutes
    COD repeatability ≤ ± 5 %
    Processing sample number per batch
    Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
    COD reactor digestion temperature 165 ± 0.5°C
    COD reactor digestion time 10 min
    COD reactor time setting switches 3 pcs
    Anti-chlorine interference (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen :
    Ammonia nitrogen determination range 0.02 to 60 mg/ L
    Ammonia nitrogen measurement accuracy ≤ ± 10 %
    Ammonia nitrogen minimum detection limit 0.01 mg/ L
    Ammonia nitrogen measurement time 10 to 15 minutes
    Ammonia nitrogen repeatability ≤ ± 5 %
    Processing sample number per batch
    Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches 3 pcs
  • Total phosphorous :
    Total phosphorous determination range 0.002 to 20 mg/ L
    Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
    Total phosphorous minimum detection limit 0.001 mg/ L
    Total phosphorous measurement time 35 to 50 minutes
    Total phosphorous repeatability ≤ ± 5 %
    Processing sample number per batch
    Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature 120 ± 0.5°C
    Total phosphorous reactor digestion time 30 min
    Total phosphorous reactor time setting switches 3 pcs
  • Turbidity :
    Turbidity determination range 0.5 to 400 NTU
    Turbidity measurement accuracy ≤ ± 5 %
    Turbidity minimum detection limit 0.1 NTU
    Turbidity measurement time 1 minute
    Turbidity repeatability ≤ ± 5 %
    Consumables for colorimetric turbidity measurement Colorimetric Cuvette
  • Light source life : 100000 hours
Multi parameter water quality analyzer LMWA-A11
  • COD :
    COD determination range 5 to 5000 mg/ L
    COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
    COD minimum detection limit 0.1 mg/ L
    COD measurement time 20 minutes
    COD repeatability ≤ ± 5 %
    Processing sample number per batch 12 pcs
    Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
    COD reactor digestion temperature 165 ± 0.5°C
    COD reactor digestion time 10 min
    COD reactor time setting switches 3 pcs
    Anti-chlorine interference (Cl) < 1000 mg/ L No effect
  • Ammonia nitrogen :
    Ammonia nitrogen determination range 0.02 to 30 mg/ L
    Ammonia nitrogen measurement accuracy ≤ ± 10 %
    Ammonia nitrogen minimum detection limit 0.01 mg/ L
    Ammonia nitrogen measurement time 10 to 15 minutes
    Ammonia nitrogen repeatability ≤ ± 5 %
    Processing sample number per batch 20 pcs
    Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
    Ammonia nitrogen reactor time setting switches 3 pcs
  • Total phosphorous :
    Total phosphorous determination range 0.002 to 10 mg/ L
    Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
    Total phosphorous minimum detection limit 0.001 mg/ L
    Total phosphorous measurement time 35 to 50 minutes
    Total phosphorous repeatability ≤ ± 5 %
    Processing sample number per batch 12 pcs
    Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
    Total phosphorous reactor digestion temperature 120 ± 0.5°C
    Total phosphorous reactor digestion time 30 min
    Total phosphorous reactor time setting switches 3 pcs
  • Turbidity :
    Turbidity determination range 0.5 to 400 NTU
    Turbidity measurement accuracy ≤ ± 5 %
    Turbidity minimum detection limit 0.1 NTU
    Turbidity measurement time 1 minute
    Turbidity repeatability ≤ ± 5 %
    Consumables for colorimetric turbidity measurement Colorimetric Cuvette
  • Light source life : 100000 hours
Multi purpose Pocket pH tester LPPT-B10
  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Different electrodes can be connceted via BNC Connector
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01)

Multi-range pocket TDS tester LPTS-A20

  • TDS range : 0 - 20 ppt
  • TDS accuracy : ± 1 % F.S.
  • TDS factor : 0.1 to 1.0 (default 0.5)
  • Calibration points : 1 - 3 points
  • TDS type range : Low range TDS

Online Conductivity Controller LOCC-A10

  • Conductivity measurement range : 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
  • Conductivity calibration points : 1 to 3 points
  • Conductivity accuracy : ±1 % F.S.
  • Conductivity resolution : 0.001/ 0.01/ 0.1/ 1
  • Conductivity calibration solutions : 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm
Online Dissolved Oxygen Controller LODC-A10
  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen Calibration points : 1 - 2 points
  • Dissolved oxygen accuracy : ± 0.5 mg / L
  • Dissolved oxygen resolution : 0.1 mg / L
  • % of saturation of oxygen range : 0.0 to 200.0 %
Online pH Controller LOPC-A10
  • pH measurement range : 01.00 to 15.00 pH
  • pH calibration points : 1 to 3 points
  • pH Buffer Solutions : USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH

Pocket Conductivity tester LPCT-A10

  • Conductivity measurement range : 1.0 to 199.9 µS/cm
  • Type of conductivity : Low range conductivity
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity calibration points : 1 point
  • Conductivity calibration solutions : 146.5 µS/cm

Pocket Conductivity tester LPCT-A11

  • Conductivity measurement range : 10 to 1999 µS/cm
  • Type of conductivity : Mid-range conductivity
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity calibration points : 1 point
  • Conductivity calibration solutions : 1413 µS/cm
Pocket Conductivity tester LPCT-A12
  • Conductivity measurement range : 0.1 to 19.99 mS/cm
  • Type of conductivity : High range conductivity
  • Conductivity accuracy : ± 1 % F.S.
  • Conductivity calibration points : 1 point
  • Conductivity calibration solutions : 12.88 mS/cm
Pocket Dissolved oxygen tester LPKDO-A10
  • Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg/L
  • % of saturation of oxygen : 0.0 to 200.0%
  • Sensor type : Polarographic dissolved oxygen probe
  • % Saturation of oxygen accuracy : ± 10 % F.S.

Pocket ORP tester LPOT-A10

  • Sensor type : Platinum sensor
  • Connector : 6 pin
  • ORP measurement range : (-999) to 999 mV
  • ORP accuracy : ± 2 mV
  • ORP resolution : 1 mV

Pocket ORP tester LPOT-A11

  • Connector : BNC
  • ORP measurement range : (-999) to 999 mV
  • ORP accuracy : ± 2 mV
  • ORP resolution : 1 mV
  • ORP calibration solutions : mV & relative mV
Pocket pH tester LPPT-A10
  • pH measurement range : 0.0 - 14.00 pH
  • Shape of electrode : Round glass pH electrode
  • pH measurement accuracy : ± 0.1 pH
  • Calibration point : 2 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Pocket pH tester LPPT-A11
  • pH measurement range : 0.0 - 14.00 pH
  • Shape of electrode : Flat pH electrode
  • pH measurement accuracy : ± 0.1 pH
  • Calibration point : 2 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Pocket pH tester LPPT-A12

  • pH measurement range : 0.0 - 14.00 pH
  • Shape of electrode : Long distance planar pH electrode
  • pH measurement accuracy : ± 0.1 pH
  • Calibration point : 2 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Pocket pH tester LPPT-A20

  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Round glass pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Pocket pH tester LPPT-A21
  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Flat pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Pocket pH tester LPPT-A22
  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Long distance planar pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Pocket pH tester LPPT-A30

  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Round glass pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Pocket pH tester LPPT-A31

  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Flat pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Pocket pH tester LPPT-A32
  • pH measurement range : pH range: (-1.00) to 15.00 pH
  • Shape of electrode : Long distance planar pH electrode
  • pH measurement accuracy : ± 0.01 pH
  • Calibration point : 1 - 3 points
  • Calibration solution : USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Pocket Salinity tester LPST-A10
  • Salinity measurement range : 0.00 to 10.00 ppt
  • Salinity accuracy : ± 1 % F.S
  • Conductivity range : 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
  • Calibration solutions : 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
  • Conductivity accuracy : ± 1 % F.S

Pocket Salinity tester LPST-A11

  • Salinity measurement range : 0.00 to 80.00 ppt
  • Salinity accuracy : ± 1 % F.S
  • Conductivity range : 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
  • Calibration solutions : 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
  • Conductivity accuracy : ± 1 % F.S

Pocket TDS tester LPTS-A10

  • TDS range : 0.5 - 100.0 ppm
  • TDS accuracy : ± 1 % F.S.
  • TDS factor : 0.4 to 1.0 (default 0.5)
  • Calibration points : 1 point
  • TDS type range : Low range TDS
Pocket TDS tester LPTS-A11
  • TDS range : 5 - 1000 ppm
  • TDS accuracy : ± 1 % F.S.
  • TDS factor : 0.4 to 1.0 (default 0.5)
  • Calibration points : 1 point
  • TDS type range : Mid-range TDS
Pocket TDS tester LPTS-A12
  • TDS range : 0.05 - 10.00 ppt
  • TDS accuracy : ± 1 % F.S.
  • TDS factor : 0.4 to 1.0 (default 0.5)
  • Calibration points : 1 point
  • TDS type range : High range TDS

Portable Chlorine Meter LPCL-A10

  • Residual chlorine/total chlorine :
    Range 0.00 to 5.00 mg/L
    Accuracy 0.001 mg/L 0.001 ABS
    Repeatability Lower detection limit ≤0.02 mg/L
  • Chlorine dioxide :
    Range 0.00 to 10.00 mg/L
    Resolution 0.001 mg/L 0.001 ABS
    Accuracy ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 %
    Lower detection limit ≤0.04 mg/L
  • Light source : LED
  • Wavelength of light : 515 nm
  • Dimension : 230 × 86 × 47 mm

Portable Conductivity Meter LPCM-A10

  • Conductivity :
    Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
    Conductivity accuracy ±0.5% F.S
    Conductivity calibration points 1 to 3 points
    Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
    Conductivity resolution 0.001, 0.01, 0.1, 1
  • Temperature :
    Temperature measuring range 0 105 °C, 32 to 221 °F
    Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
    Temperature calibration points 1 point
    Temperature resolution 0.1 °C, 0.1 °F
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear
  • Reference temperature : 25 °C
Portable Conductivity Meter LPCM-A11
  • Conductivity :
    Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
    Conductivity accuracy ±0.5% F.S
    Conductivity calibration points 1 to 5 points
    Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
    Conductivity resolution 0.001, 0.01, 0.1, 1
  • TDS :
    TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS accuracy ±1 % F.S
    TDS factor 0.01 to 1.00 (Default 0.5)
    TDS resolution 0.01, 0.1, 1
  • Temperature :
    Temperature measuring range 0 105 °C, 32 to 221 °F
    Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
    Temperature calibration points 1 point
    Temperature resolution 0.1 °C, 0.1 °F
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear and Pure water compensation
Portable Conductivity Meter LPCM-A12
  • Conductivity :
    Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
    Conductivity accuracy ±0.5% F.S
    Conductivity calibration points 1 to 5 points
    Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
    Conductivity resolution 0.001, 0.01, 0.1, 1
  • Salinity :
    Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
    Salinity accuracy ±1% F.S
    Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
    Salinity resolution 0.01, 0.1, 1
  • Temperature :
    Temperature measuring range 0 105 °C, 32 to 221 °F
    Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
    Temperature calibration points 1 point
    Temperature resolution 0.1 °C, 0.1 °F
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
  • Temperature coefficient : Linear and Pure water compensation

Portable Conductivity Meter LPCM-A13

  • Conductivity :
    Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
    Conductivity accuracy ±0.5% F.S
    Conductivity calibration points 1 to 5 points
    Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
    Conductivity resolution 0.001, 0.01, 0.1, 1
  • TDS :
    TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS accuracy ±1 % F.S
    TDS factor 0.01 to 1.00 (Default 0.5)
    TDS resolution 0.01, 0.1, 1
  • Salinity :
    Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
    Salinity accuracy ±1% F.S
    Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
    Salinity resolution 0.01, 0.1, 1
  • Resistivity :
    Resistivity range 0.00 to 20 MΩ
    Resistivity accuracy ±1% F.S
    Resistivity resolution 0.01, 0.1, 1
  • Temperature :
    Temperature measuring range 0 105 °C, 32 to 221 °F
    Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
    Temperature calibration points 1 point
    Temperature resolution 0.1 °C, 0.1 °F

Portable Dissolved oxygen meter LPRDO-A10

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L
  • Resolution : 0.1 mg / L
  • Calibration points : 1 - 2 points
  • Sensor type : Polarographic DO probe
Portable dissolved oxygen meter LPRDO-A11
  • Dissolved oxygen range : 0.0 - 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L
  • Resolution : 0.01 mg / L
  • Calibration points : 1 - 2 points
  • Sensor type : Polarographic DO probe
Portable Multi-parameter Water Quality Meter LMPWM-A10
  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Ion measurement :
    Ion measurement range 0 to 19999 ppm, mg/L, mol/L
    Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
    Ion calibration points 2 - 5 points
    Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Ion measurement :
    Ion measurement range
    Ion accuracy
    Ion calibration points
    Ion calibration solutions
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Conductivity measurement :
    Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
    Conductivity accuracy ± 0.5 % F.S.
    Conductivity calibration points 1 - 5 points
    Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
    Temperature coefficient 0.0 to 10.0 % / °C
    Compensation modes Linear or pre water
    Cell constant K = 0.1, 1, 10 or user-defined
    Normalization temperature 20 °C or 25 °C
  • TDS measurement :
    TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
    TDS accuracy ± 1 % F.S.
    TDS factor 0.1 - 1.0 (default 0.5)
  • Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Portable Multi-parameter Water Quality Meter LMPWM-A21
  • pH mode :
    pH measurement range (-2.000) to 20.000 pH
    pH accuracy ± 0.002 pH
    pH calibration points 1 - 5 points
    pH calibration solutions USA, NIST, DIN or user defined
  • ORP measurement :
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration solutions mV & relative mV
  • Dissolved oxygen :
    DO concentration range 0.00 to 20.00 mg/L
    DO accuracy ± 0.2 mg/L
    Calibration points 1 - 2 points
    Pressure correction 60.0 to 112.5 kPa, 450 - 850 mmHg
    Salinity correction 0 to 50 g/L
    % Saturation of Oxygen 0.0 to 200.0 %
    Accuracy ± 2.0 %
  • Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
  • Stability conditions : Low or high
Portable pH meter LPRPM-A10
  • pH range : (-2.00) to 16.00 pH
  • pH accuracy : ± 0.01 pH
  • pH resolution : 0.01 pH
  • Calibration points : 2 points
  • Calibration solutions : USA (pH 4.01 / 7.00 / 10.01),

Portable pH/ORP meter LPRPM-A11

  • pH range : (-2.00) to 20.00 pH
  • pH accuracy : ± 0.002 pH
  • pH resolution : 0.1, 0.01, 0.001 pH
  • Calibration points : 1 - 5 points
  • Calibration solutions : USA (pH 4.01 / 7.00 / 10.01 / 12.45), NIST(pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45), DIN (pH 1.09 / 4.65 / 6.79 / 9.23 / 12.75) or user defined

Portable Turbidity Meter LTM-A10

  • Measuring range (NTU) : 0 to 200
  • Minimum readout value (NTU) : 0.1
  • Calibration point : Nil
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Portable Turbidity Meter LTM-A11
  • Measuring range (NTU) : 0 to 100, 0 to 200
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 4
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Portable Turbidity Meter LTM-A12
  • Measuring range (NTU) : 0 to 100, 100 to 400
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 5
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light

Portable Turbidity Meter LTM-A13

  • Measuring range (NTU) : 0 to 100, 100 to 500
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light

Portable Turbidity Meter LTM-A14

  • Measuring range (NTU) : 0 to 100, 100 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Portable Turbidity Meter LTM-A15
  • Measuring range (NTU) : 0 to 100, 100 to 1000
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 7
  • Sample volume : 5 to 10 ml
  • Principle method : 90° scattered light
Portable turbidity meter LTM-A16
  • Light source : LED/860 nm (Wavelength)
  • Readings display : LCD
  • Unit switches : NTU, FTU, EBC, ASBC
  • Measurement range : 0.00-20.0; 20.01-200; 200.01-1000 NTU
  • Minimum reading : 0.001

Portable water hardness meter LPWM-A10

  • Water hardness range : 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.
  • Calibration points : 2 to 5 points
  • Calibration solution : 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L
  • Temperature compensation range : 0 - 50 °C

TSS Meter LTSS-A10

  • Measurement range : 20000 mg/L
    0.01 mg/L ~ 45000 mg/L
    0.01 mg/L ~ 120000 mg/L
  • Measurement accuracy : ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
  • Pressure range : ≤ 0.4 Mpa
  • Flow rate : ≤ 2.5 m/s, 8.2 ft./s
  • Calibration : Sample calibration
    Slope calibration
Water Activity Meter LWTM-A10
  • Range : 0 to 1.0 aw
  • Resolution : 0 to 1.0 aw
  • Accuracy : ± 0.02 aw
  • Sensor : Nonconductive humidity sensor
  • Sampling Time : 5 Minutes
Water Activity Meter with sensor LWAM-A10
  • Measuring range : Water activity 0 to 0.980 aw (no condensing )
  • Temperature range : 0 to 50°C
  • Measurement accuracy : ± 0.015 aw
  • Temperature accuracy : ± 0.5°C
  • Repeatability : ≤ 0.015 aw