Enquiry Form

info@labtron.us

Liquid Handling

We offer a varied range of high quality and durable pipette and pipette tips for maximal accuracy and precision. The universal design offer a level of compatibility and functionalities for end user convenience. The pipettes and pipette tips are designed taking into consideration every user's need and precised mode of application. The processing and packaging provide highest level of liquid handling performance.

Fixed Volume Fully Autoclavable Pipettes FVP100L

  • Test Volume : 5 μL
  • Accuracy error : 1.3 %
  • Precision error : 1.2 %

Fixed Volume Fully Autoclavable Pipettes FVP101L

  • Test Volume : 10 μL
  • Accuracy error : 0.8 %
  • Precision error : 0.8 %
Fixed Volume Fully Autoclavable Pipettes FVP102L
  • Test Volume : 20 μL
  • Accuracy error : 0.6 %
  • Precision error : 0.5 %
Fixed Volume Fully Autoclavable Pipettes FVP103L
  • Test Volume : 25 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %

Fixed Volume Fully Autoclavable Pipettes FVP104L

  • Test Volume : 50 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %

Fixed Volume Fully Autoclavable Pipettes FVP105L

  • Test Volume : 100 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %
Fixed Volume Fully Autoclavable Pipettes FVP106L
  • Test Volume : 200 μL
  • Accuracy error : 0.4 %
  • Precision error : 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP107L
  • Test Volume : 250 μL
  • Accuracy error : 0.4 %
  • Precision error : 0.2 %

Fixed Volume Fully Autoclavable Pipettes FVP108L

  • Test Volume : 500 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.2 %

Fixed Volume Fully Autoclavable Pipettes FVP109L

  • Test Volume : 1000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP110L
  • Test Volume : 2000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.15 %
Fixed Volume Fully Autoclavable Pipettes FVP111L
  • Test Volume : 5000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.15 %

Fixed Volume Pipettes FVP200L

  • Test Volume : 5 μL
  • Accuracy error : 1.3 %
  • Precision error : 1.2 %

Fixed Volume Pipettes FVP201L

  • Test Volume : 10 μL
  • Accuracy error : 0.8 %
  • Precision error : 0.8 %
Fixed Volume Pipettes FVP202L
  • Test Volume : 20 μL
  • Accuracy error : 0.6 %
  • Precision error : 0.5 %
Fixed Volume Pipettes FVP203L
  • Test Volume : 25 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %

Fixed Volume Pipettes FVP204L

  • Test Volume : 50 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %

Fixed Volume Pipettes FVP205L

  • Test Volume : 100 μL
  • Accuracy error : 0.5 %
  • Precision error : 0.3 %
Fixed Volume Pipettes FVP206L
  • Test Volume : 200 μL
  • Accuracy error : 0.4 %
  • Precision error : 0.2 %
Fixed Volume Pipettes FVP207L
  • Test Volume : 250 μL
  • Accuracy error : 0.4 %
  • Precision error : 0.2 %

Fixed Volume Pipettes FVP208L

  • Test Volume : 500 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.2 %

Fixed Volume Pipettes FVP209L

  • Test Volume : 1000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.2 %
Fixed Volume Pipettes FVP210L
  • Test Volume : 2000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.15 %
Fixed Volume Pipettes FVP211L
  • Test Volume : 5000 μL
  • Accuracy error : 0.3 %
  • Precision error : 0.15 %

Pipette Controller PPC100L

  • Aspiration speed : 25 ml < 7s
  • Dispensing speed : Motor/gravity
  • Aspiration/Dispensing speed : NA
  • Pipette type : Plastic and glass pipettes, Pasteur pipette
  • Pipette volume : 0.1 to 100mL

Pipette Controller PPC101L

  • Aspiration speed : 25 ml < 5s
  • Dispensing speed : Motor/gravity
  • Aspiration/Dispensing speed : 8 shifts
  • Pipette type : Plastic and glass pipettes, Pasteur pipette
  • Pipette volume : 0.1 to 100 ml
Pipette Pump PPP100L
  • Capacity : 2 mL
  • Color : Blue
  • Packaging : Bulk Packing
  • Quantity Per Case : 100
Pipette Pump PPP101L
  • Capacity : 10 mL
  • Color : Green
  • Packaging : Bulk Packing
  • Quantity Per Case : 100

Pipette Pump PPP102L

  • Capacity : 25 mL
  • Color : Red
  • Packaging : Bulk Packing
  • Quantity Per Case : 100

Single Channel Electronic pipette SEP100L

  • Volume Range : 0.5 – 10 μL
  • Increment : 0.01 μL
  • Test Volume : 10 μL
    1 μL
  • Accuracy Error : ±1.00 %
    ±3.50 %
  • Precision Error : 0.50 %
    3.00 %
Single Channel Electronic pipette SEP101L
  • Volume Range : 5 – 50 μL
  • Increment : 0.1 μL
  • Test Volume : 50 μL
    5 μL
  • Accuracy Error : ±0.80 %
    ±3.00 %
  • Precision Error : 0.3 %
    2.50 %
Single Channel Electronic pipette SEP102L
  • Volume Range : 30 – 300 μL
  • Increment : 1 μL
  • Test Volume : 300 μL
    30 μL
  • Accuracy Error : ±0.60 %
    ±3.00 %
  • Precision Error : 0.20 %
    0.70 %

Single Channel Electronic pipette SEP103L

  • Volume Range : 100 - 1000 μL
  • Increment : 5 μL
  • Test Volume : 1000 μL
    100 μL
  • Accuracy Error : ±0.60 %
    ±3.00 %
  • Precision Error : 0.20 %
    0.60 %

Variable Volume Fully Autoclavable Pipettes VVP100L

  • Volume Range : 0.1 - 2.5 μL
  • Increment : 0.05 μL
  • Test Volume : 2.5 μL
    1.25 μL
    0.25 μL
  • Accuracy error : 2.50 %
    3.00 %
    12.00 %
  • Precision error : 2.00 %
    3.00 %
    6.00 %
Variable Volume Fully Autoclavable Pipettes VVP101L
  • Volume Range : 0.5 - 10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.00 %
    1.50 %
    2.50 %
  • Precision error : 0.80 %
    1.50 %
    1.50 %
Variable Volume Fully Autoclavable Pipettes VVP102L
  • Volume Range : 2 - 20 μL
  • Increment : 0.5 μL
  • Test Volume : 20 μL
    10 μL
    2 μL
  • Accuracy error : 0.90 %
    1.20 %
    3.00 %
  • Precision error : 0.40 %
    1.00 %
    2.00 %

Variable Volume Fully Autoclavable Pipettes VVP103L

  • Volume Range : 5 - 50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 0.60 %
    0.90 %
    2.00 %
  • Precision error : 0.30 %
    0.60 %
    2.00 %

Variable Volume Fully Autoclavable Pipettes VVP104L

  • Volume Range : 10 - 100 μL
  • Increment : 1 μL
  • Test Volume : 100 μL
    50 μL
    10 μL
  • Accuracy error : 0.80 %
    1.00 %
    3.00 %
  • Precision error : 0.15 %
    0.40 %
    1.50 %
Variable Volume Fully Autoclavable Pipettes VVP105L
  • Volume Range : 20 - 200 μL
  • Increment : 1 μL
  • Test Volume : 200 μL
    100 μL
    20 μL
  • Accuracy error : 0.60 %
    0.80 %
    3.00 %
  • Precision error : 0.15 %
    0.30 %
    1.0 %
Variable Volume Fully Autoclavable Pipettes VVP106L
  • Volume Range : 50 - 200μL
  • Increment : 1 μL
  • Test Volume : 200 μL
    100 μL
    50 μL
  • Accuracy error : 0.60 %
    0.80 %
    1.00 %
  • Precision error : 0.15 %
    0.30 %
    0.40 %

Variable Volume Fully Autoclavable Pipettes VVP107L

  • Volume Range : 100 - 1000μL
  • Increment : 5 μL
  • Test Volume : 1000 μL
    500 μL
    100 μL
  • Accuracy error : 0.60 %
    0.70 %
    2.00 %
  • Precision error : 0.20 %
    0.25 %
    0.70 %

Variable Volume Fully Autoclavable Pipettes VVP108L

  • Volume Range : 200 - 1000μL
  • Increment : 5 μL
  • Test Volume : 1000 μL
    500 μL
    200 μL
  • Accuracy error : 0.60 %
    0.70 %
    0.90 %
  • Precision error : 0.20 %
    0.25 %
    0.30 %
Variable Volume Fully Autoclavable Pipettes VVP109L
  • Volume Range : 1000 - 5000 μL
  • Increment : 50 μL
  • Test Volume : 5000 μL
    2500 μL
    1000 μL
  • Accuracy error : 0.50 %
    0.60 %
    0.70 %
  • Precision error : 0.15 %
    0.30 %
    0.30 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP100L
  • No of Channels : 8
  • Volume Range : 0.5 -10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.50 %
    2.50 %
    4.00 %

Variable Volume Multi Channel Fully Autoclavable Pipette VMP101L

  • No of Channels : 8
  • Volume Range : 5-50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 1.00 %
    1.50 %
    3.00 %

Variable Volume Multi Channel Fully Autoclavable Pipette VMP102L

  • No of Channels : 8
  • Volume Range : 50-300 μL
  • Increment : 5 μL
  • Test Volume : 300 μL
    150 μL
    50 μL
  • Accuracy error : 0.70 %
    1.00 %
    1.50 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP103L
  • No of Channels : 12
  • Volume Range : 0.5-10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.50 %
    2.50 %
    4.00 %
Variable Volume Multi Channel Fully Autoclavable Pipette VMP104L
  • No of Channels : 12
  • Volume Range : 5-50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 1.00 %
    1.50 %
    3.00 %

Variable Volume Multi Channel Fully Autoclavable Pipette VMP105L

  • No of Channels : 12
  • Volume Range : 50-300 μL
  • Increment : 5 μL
  • Test Volume : 300 μL
    150 μL
    50 μL
  • Accuracy error : 0.70 %
    1.00 %
    1.50 %

Variable Volume Multi Channel Pipette VMP200L

  • No of Channels : 8
  • Volume Range : 0.5 -10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.50 %
    2.50 %
    4.00 %
Variable Volume Multi Channel Pipette VMP201L
  • No of Channels : 8
  • Volume Range : 5-50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 1.00 %
    1.50 %
    3.00 %
Variable Volume Multi Channel Pipette VMP202L
  • No of Channels : 8
  • Volume Range : 50-300 μL
  • Increment : 5 μL
  • Test Volume : 300 μL
    150 μL
    50 μL
  • Accuracy error : 0.70 %
    1.00 %
    1.50 %

Variable Volume Multi Channel Pipette VMP203L

  • No of Channels : 12
  • Volume Range : 0.5-10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.50 %
    2.50 %
    4.00 %

Variable Volume Multi Channel Pipette VMP204L

  • No of Channels : 12
  • Volume Range : 5-50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 1.00 %
    1.50 %
    3.00 %
Variable Volume Multi Channel Pipette VMP205L
  • No of Channels : 12
  • Volume Range : 50-300 μL
  • Increment : 5 μL
  • Test Volume : 300 μL
    150 μL
    50 μL
  • Accuracy error : 0.70 %
    1.00 %
    1.50 %
Variable Volume Pipette VVP200L
  • Volume Range : 0.1 - 2.5 μL
  • Increment : 0.05 μL
  • Test Volume : 2.5 μL
    1.25 μL
    0.25 μL
  • Accuracy error : 2.50 %
    3.00 %
    12.00 %
  • Precision error : 2.00 %
    3.00 %
    6.00 %

Variable Volume Pipette VVP201L

  • Volume Range : 0.5 - 10 μL
  • Increment : 0.1 μL
  • Test Volume : 10 μL
    5 μL
    1 μL
  • Accuracy error : 1.00 %
    1.50 %
    2.50 %
  • Precision error : 0.80 %
    1.50 %
    1.50 %

Variable Volume Pipette VVP202L

  • Volume Range : 2 - 20 μL
  • Increment : 0.5 μL
  • Test Volume : 20 μL
    10 μL
    2 μL
  • Accuracy error : 0.90 %
    1.20 %
    3.00 %
  • Precision error : 0.40 %
    1.00 %
    2.00 %
Variable Volume Pipette VVP203L
  • Volume Range : 5 - 50 μL
  • Increment : 0.5 μL
  • Test Volume : 50 μL
    25 μL
    5 μL
  • Accuracy error : 0.60 %
    0.90 %
    2.00 %
  • Precision error : 0.30 %
    0.60 %
    2.00 %
Variable Volume Pipette VVP204L
  • Volume Range : 10 - 100 μL
  • Increment : 1 μL
  • Test Volume : 100 μL
    50 μL
    10 μL
  • Accuracy error : 0.80 %
    1.00 %
    3.00 %
  • Precision error : 0.15 %
    0.40 %
    1.50 %

Variable Volume Pipette VVP205L

  • Volume Range : 20 - 200 μL
  • Increment : 1 μL
  • Test Volume : 200 μL
    100 μL
    20 μL
  • Accuracy error : 0.60 %
    0.80 %
    3.00 %
  • Precision error : 0.15 %
    0.30 %
    1.0 %

Variable Volume Pipette VVP206L

  • Volume Range : 50 - 200μL
  • Increment : 1 μL
  • Test Volume : 200 μL
    100 μL
    50 μL
  • Accuracy error : 0.60 %
    0.80 %
    1.00 %
  • Precision error : 0.15 %
    0.30 %
    0.40 %
Variable Volume Pipette VVP207L
  • Volume Range : 100 - 1000μL
  • Increment : 5 μL
  • Test Volume : 1000 μL
    500 μL
    100 μL
  • Accuracy error : 0.60 %
    0.70 %
    2.00 %
  • Precision error : 0.20 %
    0.25 %
    0.70 %
Variable Volume Pipette VVP208L
  • Volume Range : 200 - 1000μL
  • Increment : 5 μL
  • Test Volume : 1000 μL
    500 μL
    200 μL
  • Accuracy error : 0.60 %
    0.70 %
    0.90 %
  • Precision error : 0.20 %
    0.25 %
    0.30 %

Variable Volume Pipette VVP209L

  • Volume Range : 1000 - 5000 μL
  • Increment : 50 μL
  • Test Volume : 5000 μL
    2500 μL
    1000 μL
  • Accuracy error : 0.50 %
    0.60 %
    0.70 %
  • Precision error : 0.15 %
    0.30 %
    0.30 %

Variable Volume Pipette VVP210L

  • Volume Range : 2 - 10 mL
  • Increment : 0.1 mL
  • Test Volume : 10 mL
    5 mL
    2 mL
  • Accuracy error : 0.60 %
    1.20 %
    3.00 %
  • Precision error : 0.20 %
    0.30 %
    0.60 %